Product overview Fluke FLK-1662 AU

Fluke 1662 Multifunction Installation Tester delivers solid, basic installation testing features

The Fluke 1662 installation tester gives you Fluke reliability and all the basic testing power you need for day-in, day-out installation testing. It tests to all local regulations and is easy and intuitive to use. Additional helpful features like the On/Off switchable auto-start for RCD and loop test, and self-test save time and give you more confidence in your results.

  • Measures RCD switching time and tripping level (ramp test)
  • Measures trip time and current for RCD type A & AC in one test
  • Measures RCD variable current
  • Provides automatic RCD test sequence
  • Includes Z-max memory for loop tests to support easy evaluation of the highest loop test value
  • Provides unique zero adapter for fast, reliable and accurate test lead and mains cord compensation
  • Includes a phase sequence indicator
  • Comes with hard carrying case, padded carrying and waist strap, and remote control probe and lead

Features

A solid, reliable, basic installation tester

  • Tests voltage and frequency
  • Checks wiring polarity to detect broken N wires
  • Measures insulation resistance and loop and line resistance
  • Measures motor windings with continuity test
  • Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)

    Specifications: Fluke 1662 Multifunction Testers

    AC voltage measurement
    Range 500 V
    Resolution 0.1 V
    Accuracy 45 Hz – 66 Hz 0.8% + 3
    Input impedance 360 kΩ
    Overload protection 660 V rms
    Continuity testing (RLO)
    Range (autoranging) 20 Ω / 200 Ω / 2000 Ω
    Resolution 0.01 Ω / 0.1 Ω / 1 Ω
    Open Circuit Voltage >4 V
    Insulation resistance measurement (RISO)
    Accuracy of tTest voltage (at rated test current) +10%, -0%
    Test voltage 100 V
    250 V
    500 V
    1000 V
    Insulation resistance range 20 MΩ / 50 MΩ
    20 MΩ / 100 MΩ
    20 MΩ / 200 MΩ
    20 MΩ / 200 MΩ / 500 MΩ
    20 MΩ / 200 MΩ / 1000 MΩ
    Resolution 0.01 MΩ / 0.1 MΩ
    0.01 MΩ / 0.1 MΩ
    0.01 MΩ / 0.1 MΩ
    0.01 MΩ / 0.1 MΩ / 1 MΩ
    0.01 MΩ / 0.1 MΩ / 1 MΩ
    Test current 1 mA @ 50 kΩ
    1 mA @ 100 kΩ
    1 mA @ 250 kΩ
    1 mA @ 500 kΩ
    1 mA @ 1 MΩ
    Loop and line impedance (ZI)
    Range 10 Ω / 0.001 Ω / High current mΩ mode
    Resolution 0.01 Ω / 0.1 Ω / 1 Ω
    Prospective earth fault current, PSC test
    Range 1000 A / 10 kA (50 kA)
    Resolution 1 A / 0.1 kA
    Computation Prospective earth fault current (PEFC) or Prospective short circuit current (PSC) determined by dividing measured mains voltage by measured loop (L-PE) resistance or line (L-N) resistance, respectively.
    RCD testing, RCD types tested
    RCD Type A4, AC¹, G², S³
    Notes ¹Responds to AC
    ²General, no delay
    ³Time delay
    4Responds to pulsed signal
    5Responds to smooth DC signal
    Tripping speed test (ΔT)
    Current settings¹ 10-30-100-300-500-1000 mA – VAR
    10-30-100 mA
    Multiplier x ½, x 1
    x 5
    Measurement range RCD Type G 310 ms
    50 ms
    RCD Type S 510 ms
    160 ms
    Notes ¹1000 mA type AC only
    700 mA maximum type A in VAR mode
    VAR mode not available for type B.
    RCD/FI-Tripping Current Measurement/Ramp Test (IΔN)
    Current range 30% to 110% of RCD rated current¹
    Step size 10% of IΔN²
    Dwell time Type G 300 ms/step
    Type S 500 ms/step
    Measurement accuracy ±5%
    Specified trip current ranges (EN 61008-1) 50% to 100% for Type AC
    35% to 140% for Type A (>10 mA)
    35% to 200% for Type A (≤10 mA)
    50% to 200% for Type B
    ²5% for Type B
    Notes ¹30% to 150% for Type A IΔN > 10 mA
    30% to 210% for Type A IΔN = 10 mA
    20% to 210% for Type B
    Phase Sequence Indication
    Icon icon phase sequence indicator Phase Sequence indicator is active.
    General Specifications
    Size (L x W x H) 10 x 25 x 12.5 cm
    Weight (incl. batteries) 1.3 Kg
    Battery size, quantity Type AA, 6 ea.
    Sealing IP-40
    Safety Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA –s82.02.01 2000 and CAN/CSA c22.2 No. 1010 2nd edition
    Overvoltage CAT III / 500V; CAT IV 300V
    Performance EN61557-1 to EN61557-7 Second Edition and EN61557-10 Second Edition

     

     Includes:

    • 6x AA (IEC LR6) cell batteries
    • C1600 hard carrying case
    • Zero adapter
    • Heavy duty mains cord
    • STD standard test lead set
    • C1600 hard carrying case
    • Padded carrying and waist strap
    • Quick reference guide
    • TP165X remote control probe and lead
    • User’s manual on CD-ROM

     

    Manuals

    • 1662/1663/1664 FC | Users manual
    • 1662/1663/1664 FC | Users manual supplement
    • DMS Software | Users manual
    • 1662/1663/1664 FC | Quick reference guide
    • 1662/1663/1664 FC | Safety sheet
    • 1662/1663/1664 FC | Safety sheet supplement
    • 1662/1663/1664 FC | Calibration manual
    • 1662/1663/1664 FC | Calibration manual supplement
    • DMS Software | Quick reference guide