Product Overview

Combines the functions of a clamp meter, oscilloscope, data logger, and digital power meter in one, making this unit ideal for measurements on switching loads such as variable frequency drives, electronic lighting, and UPS systems. Also, it’s Hall Effect measurement system measures DC currents without breaking the circuit.

One of the leading wattage meters of the world, the multi-faceted Fluke 345 is packed with features such as a bright, colour display to analyse the harmonic spectrum, a low-pass filter to remove high frequency noise and a high EMC immunity design, making the Fluke 345 power analyser ideal for troubleshooting power quality on switching loads. The internal memory of this electric power meter enables long-term power quality logging for analysis of trends or intermittent problems. Additionally, the Hall Effect clamp meter design makes measurement of dc current possible without the need to break the circuit.

Features

  • AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit
  • Highest safety rating: 600 V CAT IV power analyser is rated for use at the service entrance
  • Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic
  • loads with low-pass filter

  • Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics
  • Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems
  • Troubleshoot harmonics: Analyse and log harmonics digitally or graphically
  • Inrush current: Capture and analyse nuisance tripping, from 3 seconds to 300 seconds
  • Easy to use: Easily confirm power meter setup with large backlit colour display of waveforms and trends
  • USB download: Download logged data with PowerLog application software to view trends and screenshots, analyse and create reports simply.
  • Battery eliminator: powers the instrument when performing extended logging sessions.
  • 3-Phase power: Built in capability for balanced loads
  • View graphs and generate reports: Use power analyser with included Power Log software

Besides effectively performing basic tasks like measuring wattage, the Fluke 345 power meters offer the ease of use, portability and flexibility needed to resolve most power issues in commercial, industrial and residential settings.

Applications

  • Setup and troubleshoot variable frequency drives and UPS systems – Verify correct operation by measuring key power quality parameters
  • Harmonics measurements – Uncover harmonic issues that can damage or disrupt critical equipment
  • Inrush capture – Check start-up current where spurious resets or nuisance circuit breaker tripping occurs
  • Load studies – Verify electrical system capacity before adding loads

Specifications

Current Measurement
Measuring Range 0 to 2000 A DC or 1400 AC RMS
Autorange Facility 40 A/400 A/2000 A
Resolution 10 mA in 40 A range
100 mA in 400 A range
1 in 2000 A range
Accuracy
DC and DC RMS I > 10 A: ±1.5% rdg ±5 digits
I < 10 A: ±0.2 A
AVG I > 10 A: ±3% rdg ±5 digits
I < 10 A: ±0.5 A
Pk I > 10 A: ±5% rdg ±5 digits
I < 10 A: ±0.5 A
AHr I > 10 A: ±2% rdg ±5 digits
I < 10 A: ±0.5 AHr
CF (Crest Factor) 1.1 ≤ CF < 3: ±3% rdg ±5 digits
3 ≤ CF < 5: ±5% rdg ± 5 digits
Resolution: 0.01
RPL (Ripple) 2% ≤ RPL < 100%: ±3% rdg ±5 digits
100% ≤ RPL < 600%: ±5% rdg ± 5 digits
Resolution: 0.01%
Voltage Measurement
Measuring Range 0 to 825 V DC or AC RMS
Autorange Facility 4 V/40 V/400 V/750 V
Resolution 1 mV in 4 V range
10 mV in 40 V range
100 mV in 400 V range
1 V in 750 V range
DC and DC RMS V > 1 V: ±1% rdg ±5 digits
V < 1 V: ± 0.02 V
AVG V > 1 V: ±3% rdg ±5 digits
V < 1 V: ± 0.03 V
Pk V > 1 V: ±5% rdg ±5 digits
V < 1 V: ± 0.03 V
CF (Crest Factor) V > 1 V: ±5% rdg ±5 digits
V < 1 V: ±5% rdg ± 5 digits
Resolution: 0.01
RPL (Ripple) 2% ≤ RPL < 100%: ±3% rdg ± 5 digits
100% ≤ RPL < 600%: ±5% rdg ± 5 digits
Resolution: 0.1%
Harmonics
THD (Total Harmonic Distortion) 1% ≤ THD < 100%: ±3% rdg ± 5 digits
100% ≤ THD < 600%: ±5% rdg ± 5 digits
Resolution: 0.1%
DF (Distortion Factor) 1% ≤ DF < 100%: ±3% rdg ± 5 digits
Resolution: 0.1%
H02 ≤ Vharm < H13: ±5% rdg ± 2 digits
H13 ≤ Vharm ≤ H30: ± 10% rdg ± 2 digits
Watts Measurement (Single – and Three-Phase)
Measuring Range 0 to 1650 kW DC or 1200 kW AC
Autoranging Facility 4, 40, 400, 1650 kW AC
Resolution 1 W in 4 kW
10 W in 40 kW
100 W in 400 kW
1 kW in 1200 kW
Accuracy 2.5% rdg ± 5 digits
W1ø <2 kW ± 0.08 kW
W3ø <4 kW ± 0.25 kW
VA Measurement (Single – and Three-Phase)
Measuring Range 0 to 1650 kVA DC or 1200 kVA AC
Autorange Facility 4, 40, 400, 1650 kVA
Resolution 1 VA in 4 kVA
10 VA in 40 kVA
100 VA in 400 kVA
1 kVA in 1200 kVA
Accuracy VA >2 kVA: 2.5% rdg ± 5 digits
VA <2 kVA: ±0.08 kVA
VAR Measurement (Single – and Three-Phase)
Measuring Range 0 to 1250 kVAR
Autorange Facility 4, 40, 400, 1200 kVAR
Resolution 1 VAR in 4 kVAR
10 VAR in 40 kVAR
100 VAR in 400 kVAR
1 kVAR in 1200 kVAR
Accuracy VA >4 kVAR: 2.5% rdg ± 5 digits
VA <4 kVAR: ±0.25 kVAR
Power Factor Range 0.3 >PF <0.99
Power Factor (Single – and Three-Phase)
Measuring Range 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive)
Resolution 0.001
Accuracy ±3°
Frequency Range 15 Hz to 1 kHz
Displacement Power Factor
Measuring Range 0.3 capacitive and 1.0 to 0.3 inductive (72.5° capacitive and 0 to 72.5° inductive)
Resolution 0.001
Accuracy ±3°
Frequency Range 15 to 22 Hz and 45 to 65 Hz
Kilowatt Hour (kWHr)
Measuring Range 40,000 kWHr
Autorange Facility 1, 40, 400, 4000, 40,000 kWHr
Resolution 1 WHr in 4 kWHr
10 WHr in 40 kWHr
100 WHr in 400 kWHr
1 kWHr in 4,000 kWHr
10 kWHr in 40,000 kWHr
Accuracy kWHr >2 kWHr: ±3% ± 5 digits
kWHr <2 kWHr: ±0.08 kWHr
All Watts /VA /VAR /PF Measurements Frequency range: DC and 15 Hz to 1 kHz
Current range: 10 to 1400 A RMS
Voltage range: 1 to 825 V RMS
Maximum input: 825 V RMS/1400 A RMS
Maximum overload: 1000 V RMS/10,000 A
Frequency Measurement
Measuring Range 15 Hz to 1 kHz
Resolution 0.1 Hz
Accuracy 15 to 22 Hz ± 0.5% rdg
40 to 70 Hz ± 0.5% rdg
15 to 1000 Hz ± 1% rdg
Current Range 10 to 1400 A RMS
Voltage Range 1 to 825 V RMS
Current Measurement
Ranges 10/20/40/100/200/400/1000/2000 A
Resolution 1 A in 40 A
10 A in 400 A
50 A in 2000 A
Accuracy ±3% rdg ± 1 pixel
Maximum Overload 10,000 A
Voltage Measurement
Ranges 4/10/20/40/100/200/400/1000 V
Resolution 100 mV in 4 V
1 V in 40 V
10 V in 400 V
31.25 V in 1000 V
Accuracy ±2% rdg ± 1 pixel
Maximum Overload 1000 V RMS
Frequency Range DC and 15 to 600 Hz
Time Base 2.5, 5, 10, 25, 50 ms/div
Refresh Rate 0.5 seconds
Maximum Sampling Rate 15.625 kHz
Inrush Current Function
Ranges 40, 400, and 2000 A
Resolution 10 mA in 40 A range
100 mA in 400 A range
1 A in 2000 A range
Accuracy I > 10 A: ±5% rdg ± 1 pixel
I < 10 A: ±0.5 A
Maximum Overload Maximum overload 10,000 A or RMS x frequency <400,000
Capture Time 1, 3, 10, 30, 100, and 300 s
Maximum Sampling Rate 15.625 kHz
Logging Memory
Logging Areas Three areas that can be used individually or combined into one large area
Averaging Periods 1, 2, 5, 10, 30 s, 1, 5, 10, 15 min, and custom
General Specifications
Display Color transmissive LCD 320 x 240 pixels (70 mm diagonal) with 2 level backlight
Power Supply Battery type 1.5 V Alkaline AA MN 1500 or IEC LR6 x 6
Battery Life Typically >10 hours (backlight on full)
>12 hours (backlight reduced)
Battery Eliminator BE345 Input: 110/230 V, 50/60 Hz
Output: 15 V DC, 300 mA
Reference Conditions All accuracies stated at 73.4 ± 1.8°F (23 ± 1°C)
Operating Temperature 32 to 122°F (0 to 50°C)
Temperature Coefficient of Current ≤± 0.15% of rdg per °C
Temperature Coefficient of Voltage ≤± 0.15% of rdg per °C
Maximum Relative Humidity 80 % for temperatures up to 87°F (31°C) decreasing linearly to 50% relative humidity at 104°F (40°C)
Maximum Operating Altitude 6561.7′ (2000 m)
Mechanical
Cleaning The unit can be cleaned with an Isopropanol impregnated cloth. Do not use abrasives or other solvents.
Jaw Capacity 2.3″ (58 mm) diameter
Jaw Opening 2.4″ (60 mm)
Dimensions 12 x 3.75 x 2″ (300 x 98 x 52 mm
Weight 1.8 lbs (820 g) batteries included
Electrical Safety
Maximum Safe Working Voltages Current measurement: 600 V AC RMS or DC between uninsulated conductor and ground
Voltage measurement: 600 V AC RMS or DC between either input terminal and ground, or 825 V between energized phase voltages (delta power config.)
EMC
Emission IEC/EN 61326-1:1997 class B
Immunity IEC/EN 61326-1:1997