Description
(item no. 4867996)
Amprobe’s newest wire tracer combines a Receiver and powerful Transmitter to locate energized and de-energized wires, breakers, and fuses without having to disconnect any equipment. The Receiver features four tracing modes optimized for a range of applications. Its fully automatic breaker tracing capability saves time and eliminates the confusion of multiple false positives by detecting the highest recorded signal in a breaker or fuse. The Transmitter utilizes two optimized frequencies that allows for a clean and reliable signal. The Signal Clamp can be used in applications where there is no access to bare conductors by enabling the Transmitter to induce a signal into a wire through insulation. Whether you’re a novice user or an expert, the AT-6000 Amprobe Advanced Wire Tracer kit will help you get the job done fast.
Features
- Traces wires in walls, ceilings, floors and corners
- Locates breakers and fuses
- Pinpoints shorts and opens
- High resolution 2.5″ TFT LCD color display
- Three Transmitter signal modes
- “High Signal” mode for normal circuits
- “Low Signal” mode for precision tracing in difficult areas
- “Loop” mode for closed loop de-energized circuits
- Four Receiver tracing modes
- “Quick Scan” mode allows for quick wire detection at a longer distance
- “Precision” mode precisely pinpoints wires or faults located behind walls, floors, or ceilings
- “Breaker Identification” mode facilitates quick and easy breaker locating
- “Non-Contact Voltage Detection” mode utilizes passive tracing without the Transmitter to verify if a wire is energized
- Two automatically selected frequency modes for reliable tracing on energized and de-energized circuits
- Comes with custom Amprobe hard carrying case, test leads, CT-400 signal clamp, and accessories
- Compatible with optional TIC 410A Hot Stick attachment to extend your reach
Specifications
| Specifications |
AT-6000-R Receiver |
AT-6000-T Transmitter |
CT-400 Signal Clamp |
| Measurement Category |
CAT III 600 V |
CAT III 600 V |
CAT IV 600 V, CAT III 1000 V |
| Operating voltage |
0 to 600 V AC/DC |
0 to 600 V AC/DC |
0 to 1000 V AC |
| Operating frequency |
Energized: 6.25 kHz De-Energized: 32.768 kHz |
Energized: 6.25 kHz De-Energized: 32.768 kHz |
Wire tracing: 32.768 kHz AC current measurement: 45 Hz to 400 Hz |
| Hazardous voltage detection |
See NCV detection |
> 30 V AC/DC |
N/A |
| Signal indications |
Numeric, bar graph display and audible beep |
LEDs and audible beep |
N/A |
| Response time |
Tip Sensor (energized/de-energized): 500 MS NCV: 500 MS Battery voltage monitoring: 5 sec |
Line voltage monitoring: 1 sec Battery voltage monitoring: 5 sec |
Instantaneous |
| Current output of signal (typical) |
N/A |
Energized circuit: HI mode: 60 mA RMS LO mode: 30 mA RMS De-energized circuit: HI mode: 130 mA RMS LO mode: 40 mA RMS Loop mode: 160 mA RMS |
1 mA/A for AC current measurement with multimeter |
| Signal voltage output (nominal) |
N/A |
De-energized circuit: LOW: 29 V RMS, 120 Vp-p HIGH: 33V RMS, 140 Vp-p With CT-400: loop model: 31 V RMS, 120 Vp-p |
De-energized circuit: 2.4 V RMS, 24 Vp-p |
| Range detection (open air) |
Tip sensor (Energized): Max distance via air: up to 20 ft (6.1 m) Pinpointing: approx. 1.97 in (5 cm) Tip sensor (De-energized): Max distance via air: up to 14.7 ft (4.5 m) Pinpointing: approx. 1.97 in (5 cm) NCV detection (40 to 400 Hz): Max. sensitivity: 90 V up to 6.56 ft (2 m) Min. sensitivity: 600 V up to 0.39 in (1 cm) |
N/A |
N/A |
| Kit Contains |
AT-6020 kit |
AT-6030 kit |
| AT-6000-R Receiver |
• |
• |
| AT-6000-T Transmitter |
• |
• |
| TL-6000 Test Lead and Accessory Kit |
• |
• |
| CC-6000 Hard Carrying Case |
• |
• |
| User Manual |
• |
• |
| 1.5 V AA (IEC R6) Batteries (12) (not installed) |
• |
– |
| Rechargeable Batteries (12) (not installed) |
– |
• |
| Battery Chargers (3) |
– |
• |
| CT-400 Signal Clamp |
– |
• |
|
|
|
|
| Model Name |
Description |
| AT-6030 |
Amprobe AT-6030 Advanced Wire Tracer Kit
- Traces wires in walls, ceilings, floors and corners
- Locates breakers and fuses
- Pinpoints shorts and opens
- High resolution 2.5″ TFT LCD color display
- Three Transmitter signal modes
- “High Signal” mode for normal circuits
- “Low Signal” mode for precision tracing in difficult areas
- “Loop” mode for closed loop de-energized circuits
- Four Receiver tracing modes
- “Quick Scan” mode allows for quick wire detection at a longer distance
- “Precision” mode precisely pinpoints wires or faults located behind walls, floors, or ceilings
- “Breaker Identification” mode facilitates quick and easy breaker locating
- “Non-Contact Voltage Detection” mode utilizes passive tracing without the Transmitter to verify if a wire is energized
- Two automatically selected frequency modes for reliable tracing on energized and de-energized circuits
- Comes with custom Amprobe hard carrying case, test leads, and accessories
- Compatible with optional TIC 410A Hot Stick attachment to extend your reach, HS-1 magnetic hanger, and TL-7000-25 m test lead
Included Accessories: AT-6000-R Receiver, AT-6000-T Transmitter, TL-6000 Test Lead and Accessory Kit, CT-400 Signal Clamp, CC-6000 Hard Carrying Case, Rechargeable Batteries, Battery Chargers, User Manual |
Download
Explore more from our collection.
Reviews